🚨 Poruchy a závady 18

Vyhledejte svou poruchu podle názvu – uvidíte příčinu a doporučené řešení.

Porucha / závadaPříčinaŘešení
The display shows no data. The boiler is not connected to the network. Connect the boiler to the electrical power network (230V/50Hz) with appropriate cable with plug.
The worm feeder doesn't work. The cable of the engine is disconnected / damaged. Connect the engine / change the cable to the engine.*
The thermal protection of the engine was activated repeatedly. The engine was overheated and the thermal protection was activated. Let the engine cool down, after cooling the engine will start again.
The boiler drive is working, but the worm feeder doesn't work The worm feeder is blocked (stone, etc.) Dismantle the worm feeder and remove the problem. Re-assemble the device.*
The worm gear is moving but the fuel is not being transported into the combustion area. There is no fuel in the container. Fill the container with recommended fuel.
The boiler ventilator doesn't work. The cable of the ventilator has been disconnected / damaged. Connect (change) the cable to the ventilator.*
The ventilator is noisy. The ventilator is broken. Change the ventilator.*
During the boiler modulation at the lowest output, the ventilator does not turn. The set values of ventilator speed (revolutions) are too low. Increase the values of the ventilator turns so that continuous operation of the ventilator is ensured.
The water from the emergency extinguishing system runs in the fuel container. The fuel has burnt off in the fuel container and the thermostatic valve was opened. Remove the wet fuel from the boiler, refill the container with the new fuel and put the boiler into the operation.
The water from the emergency extinguishing system drops in the fuel container. The paraffin plug is not tight. Change the thermostatic valve.
Water drops appear on the walls of fuel container. Wet fuel is used in the boiler. Fill the container with dry fuel.
The boiler can't reach the full nominal capacity. The time from the firing was too short. Let the boiler fire up properly.
The exhaust gas temperature is higher than is recommended in the user's manual. Different fuel used (high humidity, heating power etc.). Fill the container with appropriate fuel.
Smoke appears in the fire room or in the fuel container. The ceramic reflector is not installed in the boiler. Install the ceramic reflector according to the user's manual.
The boiler is coated with smoke particles in a short period of time. Fire door and/or the upper boiler cover and/or the fuel container cover are not closed properly. Close the fire door and/or the upper cover of the boiler and/or the fuel container cover.
The boiler is repeatedly overheated The boiler is repeatedly overheated Set the boiler capacity to the nominal capacity (see Instruction Control Unit manual).
The ash on the grate forms clogs. The grate is full of dust and ash. Clean the grate.
A great quantity of unburned fuel appears in the ashtray. Recommended fuel was not used for burning. Fill the container with appropriate fuel (see chapter 3).

ℹ️ Informativní přehled z výrobcova manuálu. Závěrečné posouzení a opravu vždy svěřte servisnímu technikovi.